层流手术室净化布置空调管道如何合适

来源:http://www.henganjh.cn │ 发表时间:2019-08-07 

  层流手术室净化空调管道布局,如何适当的空调调试需要知道在生活中,所以很重要的是要在手术室净化的作用,我们更熟悉净化手术室,所以我们不知道如何布局的空调管道是正确的,所以我们有必要了解适当的手术室净化空调管道布局。
  Layout of air-conditioning pipes for laminar flow operating room purification, how to properly adjust air-conditioning needs to know in life, so it is very important to purify the role of the operating room, we are more familiar with purifying the operating room, so we do not know how to layout the air-conditioning pipes is correct, so we need to understand the appropriate operating room purification air-conditioning pipes. Layout.
层流手术室净化
  层流手术室净化布置净化空调风管,应使风管占用的建筑空间较少,且不妨碍生产运行,常沿墙、立柱、楼板梁或房屋安装,安装在支架或吊架上。手术室净化空调风管除尘风管应尽可能垂直或倾斜敷设。倾角与水平面的夹角大于45°。必须水平敷设或倾斜角小于30°时敷设。应采取措施,如增加流量,建立一个明确的销售港口。输送含有蒸汽或液滴的气体时。坡度不小于0.005。所述风管最低点及风机底部均设有水封排水管。注意水封高度应满足各种工况的要求。可燃气体管道、可燃液体管道、电线、排水管不得通过风管内腔。也不可沿管道的外墙敷设。可燃气体管道和可燃液体管道不得通过风机室。当风管装有电加热器时。电热器前后800毫米范围内的风管、穿越火源等易燃性房间的风管和保温材料应采用不燃材料。风管应配备必要的调节和测量装置(如阀门、压力表、温度计、测量孔、取样孔等)或预留用于安装测量装置,并设置在便于操作和观察的位置。风管的布置应直通式和直通式,避免复杂的局部配件。弯头、三通等管件应合理布置,与气管的连接应合理,以降低极限和噪音。手术室净化空调风道的布置应采用锥型或雨帽式。
  The air duct of laminar flow operating room should occupy less building space and not hinder production and operation. It is often installed along walls, columns, floor beams or houses and installed on brackets or hangers. The air duct for cleaning air conditioning in operating room should be laid vertically or obliquely as possible. The angle between inclination and horizontal plane is more than 45 degrees. It must be laid horizontally or with an inclination angle less than 30 degrees. Measures should be taken, such as increasing the flow rate and establishing a clear sales port. When conveying gas containing steam or droplets. The slope is not less than 0.005. The lowest point of the air duct and the bottom of the fan are provided with water-sealed drainage pipes. Attention should be paid to the water seal height to meet the requirements of various working conditions. Flammable gas pipelines, flammable liquid pipelines, wires and drainage pipes shall not pass through the air duct cavity. It should not be laid along the outer wall of the pipeline. The flammable gas pipeline and the flammable liquid pipeline shall not pass through the fan room. When the air duct is equipped with an electric heater. The air ducts in 800 mm range before and after the electric heater, the air ducts passing through flammable rooms such as fire sources and the insulation materials should be made of non-combustible materials. The air duct shall be equipped with necessary adjusting and measuring devices (such as valves, pressure gauges, thermometers, measuring holes, sampling holes, etc.) or reserved for the installation of measuring devices, and shall be set at positions convenient for operation and observation. The arrangement of air duct should be straight-through and straight-through, avoiding complicated parts. The elbow, tee and other pipe fittings should be reasonably arranged, and the connection with the gas pipe should be reasonable, so as to reduce the limit and noise. Conical or raincap type air ducts should be used for cleaning air conditioning in operating room.
  如何在层流手术室净化中布置空调风管是值得学习的,为了更好的方便我们手术室净化的操作,如何在以上手术室净化中布置空调风管是我们提供的。如果您想了解更多关于手术室净化的信息,欢迎登录官网http://www.henganjh.cn查询!
  How to arrange air conditioning ducts in laminar flow operating room purification is worth learning. In order to better facilitate the operation of our operating room purification, how to arrange air conditioning ducts in the above operating room purification is provided by us. If you want to know more about the cleaning of the operating room, you are welcome to visit the official website http://www.henganjh.cn!